Array reconstruction engineering

RAID Data Recovery

Professional reconstruction of failed, degraded and inaccessible RAID arrays—from small business servers to complex enterprise storage.

Every member preservedVirtual reconstruction firstController-independent analysis

Recognise the warning signs

When a RAID array needs professional attention

RAID recovery is time-sensitive. Rebuilds, initialization and controller changes can transform a recoverable configuration problem into permanent overwrite.

01

Array degraded or offline

The controller reports a degraded, failed, foreign, missing or offline virtual disk.

02

Multiple drive failure

More than one member is failed, missing, unstable or rebuilding incorrectly.

03

Controller or configuration loss

The RAID controller failed, was replaced, reset or lost its virtual-disk configuration.

04

Rebuild failure

A rebuild stopped, completed with errors or made the volume inaccessible.

05

File system or volume corruption

The logical volume mounts incorrectly, appears RAW or contains damaged databases and virtual machines.

06

Accidental initialization or reconfiguration

The array was initialized, recreated, expanded, migrated or configured with the wrong parameters.

Enterprise storage expertise

RAID levels and failure scenarios we handle

Mind Merge reconstructs arrays according to their exact controller metadata, member condition, stripe geometry, parity method and logical storage layout.

  • RAID 0, RAID 1 and RAID 10 arrays
  • RAID 5 and RAID 6 parity reconstruction
  • Hardware RAID controllers and server arrays
  • Software RAID and operating-system-managed arrays
  • SAS, SATA, SSD and mixed enterprise storage
  • Virtual disks, databases and virtual machines
Configuration

Lost metadata and controller failure

Foreign configuration, controller replacement, reset configuration and missing virtual disks.

Physical

Failed or unstable member disks

Bad sectors, head failure, firmware faults and intermittent SAS or SATA members.

Rebuild

Interrupted or incorrect reconstruction

Wrong member replacement, partial rebuild, stale parity and degraded arrays.

Logical

Damaged volumes and file systems

RAW volumes, corrupted partitions, damaged virtual machines, databases and application data.

Recovery capability matrix

RAID reconstruction coverage

Each array is reconstructed virtually from preserved member images before file-system recovery begins.

RAID typeDisk imagingMetadata analysisVirtual rebuildParity recoveryFile-system recovery
RAID 0
RAID 1
RAID 5
RAID 6
RAID 10
Software RAID

Controlled recovery workflow

How we reconstruct failed RAID storage

The original disks remain unchanged while the array is rebuilt virtually from sector-level images.

01

Preserve every member disk

Each RAID member is documented and acquired independently to prevent controller writes, rebuild activity and further media loss.

02

Determine the original geometry

Engineers identify drive order, stripe size, parity rotation, offsets, member roles and controller metadata.

03

Assess failed and stale members

Unstable drives are stabilized and imaged while stale, replaced or partially rebuilt members are compared carefully.

04

Reconstruct the virtual array

The correct RAID geometry is rebuilt virtually without writing to the original disks or controller.

05

Validate volumes and recover data

File systems, virtual machines, databases and business data are checked for consistency before secure delivery.

Protect the remaining data

What not to do after a RAID failure

Stop activity once an array becomes degraded, offline or inconsistent. Every write, rebuild or initialization can alter parity and member data.

Do not initialize the array

Initialization may overwrite metadata, parity or file-system structures.

Do not force disks online

A stale or incorrect member can corrupt the logical array when forced into service.

Do not start repeated rebuilds

Rebuilds stress weak disks and may propagate corruption across healthy members.

Do not change disk order

Label every bay and cable before removing drives from the server or enclosure.

Do not replace the controller blindly

Controller firmware and metadata compatibility can affect configuration import.

Keep every original and replacement disk

Old, failed and spare members may contain essential stripes or metadata.

Controller and platform ecosystem

RAID technologies we work with

Support spans major enterprise controllers, server platforms and storage architectures. Brand names are shown for compatibility reference only.

Dell PERC logoDell PERC
HPE Smart Array logoHPE Smart Array
Broadcom / LSI logoBroadcom / LSI
Adaptec logoAdaptec
Areca logoAreca
Intel RAID logoIntel RAID
Lenovo ThinkSystem logoLenovo ThinkSystem
IBM ServeRAID logoIBM ServeRAID
Supermicro logoSupermicro
Synology logoSynology

Dell PERC • HPE Smart Array • Broadcom / LSI • Adaptec • Areca • Intel RAID • Lenovo ThinkSystem • IBM ServeRAID • Supermicro • Synology

All trademarks and logos belong to their respective owners. They are displayed only to identify commonly handled products. Mind Merge is an independent professional data recovery company and is not affiliated with or endorsed by the manufacturers shown.

RAID recovery questions

Frequently asked questions

Early decisions after an array failure can materially affect the recovery outcome.

Can data be recovered after two drives fail in RAID 5?

Sometimes, but RAID 5 normally tolerates only one failed member. Recovery depends on the condition of all disks, whether one failure is partial, and whether a rebuild or reconfiguration has overwritten parity or data.

Should I replace a failed disk and start a rebuild?

Not before professional assessment when the data is important. A rebuild reads every surviving member heavily and can fail if another disk is weak. It can also overwrite useful evidence when the wrong member or geometry is used.

Do you need the original RAID controller?

It is helpful in some cases but not always essential. We can often reconstruct the array virtually from member disks and metadata, provided the original geometry can be determined.

Can you recover RAID after controller configuration loss?

Yes, in many cases. We analyse controller metadata, disk order, stripe size, parity layout, offsets and volume structures to rebuild the virtual disk safely.

Can virtual machines and databases be recovered from RAID?

Yes. After the array is reconstructed, we assess the file system and recover VMware, Hyper-V, database and application data according to its consistency and damage level.

Should all RAID disks be sent for diagnosis?

Yes. Include every original, failed, replaced and spare disk where possible. A disk believed to be failed may contain critical stripes or metadata needed for reconstruction.

Failed or degraded RAID?

Stop the array and preserve every disk.

Contact Mind Merge before rebuilding, initializing or replacing additional members. We will help you preserve the safest recovery path.